[PATCH 2/3] dt-bindings: iio: adc: stm32: add optional min-sample-time
From: Fabrice Gasnier
Date: Tue Jul 18 2017 - 08:37:41 EST
STM32 ADC allows each channel to be sampled with a different sampling
time. There's an application note that deals with this: 'How to get
the best ADC accuracy in STM32...' It basically depends on analog input
signal electrical properties (depends on board).
Add optional 'min-sample-time' property so this can be tuned in dt.
Signed-off-by: Fabrice Gasnier <fabrice.gasnier@xxxxxx>
---
Documentation/devicetree/bindings/iio/adc/st,stm32-adc.txt | 5 +++++
1 file changed, 5 insertions(+)
diff --git a/Documentation/devicetree/bindings/iio/adc/st,stm32-adc.txt b/Documentation/devicetree/bindings/iio/adc/st,stm32-adc.txt
index 8310073..9cd964b 100644
--- a/Documentation/devicetree/bindings/iio/adc/st,stm32-adc.txt
+++ b/Documentation/devicetree/bindings/iio/adc/st,stm32-adc.txt
@@ -74,6 +74,11 @@ Optional properties:
* can be 6, 8, 10 or 12 on stm32f4
* can be 8, 10, 12, 14 or 16 on stm32h7
Default is maximum resolution if unset.
+- min-sample-time: Minimum sampling time in nanoseconds.
+ Depending on hardware (board) e.g. high/low analog input source impedance,
+ fine tune of ADC sampling time may be recommended.
+ This can be either one value or an array that matches 'st,adc-channels' list,
+ to set sample time resp. for all channels, or independently for each channel.
Example:
adc: adc@40012000 {
--
1.9.1