[PATCH 4.9 04/72] net/phy: micrel: configure intterupts after autoneg workaround
From: Greg Kroah-Hartman
Date: Wed Jul 19 2017 - 06:25:30 EST
4.9-stable review patch. If anyone has any objections, please let me know.
------------------
From: Zach Brown <zach.brown@xxxxxx>
commit b866203d872d5deeafcecd25ea429d6748b5bd56 upstream.
The commit ("net/phy: micrel: Add workaround for bad autoneg") fixes an
autoneg failure case by resetting the hardware. This turns off
intterupts. Things will work themselves out if the phy polls, as it will
figure out it's state during a poll. However if the phy uses only
intterupts, the phy will stall, since interrupts are off. This patch
fixes the issue by calling config_intr after resetting the phy.
Fixes: d2fd719bcb0e ("net/phy: micrel: Add workaround for bad autoneg ")
Signed-off-by: Zach Brown <zach.brown@xxxxxx>
Reviewed-by: Andrew Lunn <andrew@xxxxxxx>
Reviewed-by: Florian Fainelli <f.fainelli@xxxxxxxxx>
Signed-off-by: David S. Miller <davem@xxxxxxxxxxxxx>
Signed-off-by: Greg Kroah-Hartman <gregkh@xxxxxxxxxxxxxxxxxxx>
---
drivers/net/phy/micrel.c | 2 ++
1 file changed, 2 insertions(+)
--- a/drivers/net/phy/micrel.c
+++ b/drivers/net/phy/micrel.c
@@ -622,6 +622,8 @@ static int ksz9031_read_status(struct ph
if ((regval & 0xFF) == 0xFF) {
phy_init_hw(phydev);
phydev->link = 0;
+ if (phydev->drv->config_intr && phy_interrupt_is_valid(phydev))
+ phydev->drv->config_intr(phydev);
}
return 0;