Re: [PATCH v2 2/4] can: fixed-transceiver: Add documentation for CAN fixed transceiver bindings
From: Oliver Hartkopp
Date: Wed Jul 26 2017 - 13:06:05 EST
On 07/26/2017 06:41 PM, Andrew Lunn wrote:
On Mon, Jul 24, 2017 at 06:05:19PM -0500, Franklin S Cooper Jr wrote:
+
+Optional:
+ max-arbitration-speed: a positive non 0 value that determines the max
+ speed that CAN can run in non CAN-FD mode or during the
+ arbitration phase in CAN-FD mode.
Hi Franklin
Since this and the next property are optional, it is good to document
what happens when they are not in the DT blob. Also document what 0
means.
+
+ max-data-speed: a positive non 0 value that determines the max data rate
+ that can be used in CAN-FD mode. A value of -1 implies
+ CAN-FD is not supported by the transceiver.
-1 is ugly. I think it would be better to have a missing
max-data-speed property indicate that CAN-FD is not supported.
Thanks Andrew! I had the same feeling about '-1' :-)
And
maybe put 'fd' into the property name.
Good point. In fact the common naming to set bitrates for CAN(FD)
controllers are 'bitrate' and 'data bitrate'.
'speed' is not really a good word for that.
Finally, @Franklin:
A CAN transceiver is limited in bandwidth. But you only have one RX and
one TX line between the CAN controller and the CAN transceiver. The
transceiver does not know about CAN FD - it has just a physical(!) layer
with a limited bandwidth. This is ONE limitation.
So I tend to specify only ONE 'max-bitrate' property for the
fixed-transceiver binding.
The fact whether the CAN controller is CAN FD capable or not is provided
by the netlink configuration interface for CAN controllers.
Regards,
Oliver