Re: [PATCH v2 2/3] dt-bindings: iio: adc: stm32: add optional st,min-sample-time-nsecs
From: Jonathan Cameron
Date: Wed Aug 09 2017 - 09:14:07 EST
On Thu, 3 Aug 2017 12:01:54 -0500
Rob Herring <robh@xxxxxxxxxx> wrote:
> On Mon, Jul 24, 2017 at 06:10:39PM +0200, Fabrice Gasnier wrote:
> > STM32 ADC allows each channel to be sampled with a different sampling
> > time. There's an application note that deals with this: 'How to get
> > the best ADC accuracy in STM32...' It basically depends on analog input
> > signal electrical properties (depends on board).
> >
> > Add optional 'st,min-sample-time-nsecs' property so this can be tuned
> > in dt.
> >
> > Signed-off-by: Fabrice Gasnier <fabrice.gasnier@xxxxxx>
> > ---
> > Changes in v2:
> > - Use 'st,min-sample-time-nsecs' instead of 'min-sample-time'.
> > ---
> > Documentation/devicetree/bindings/iio/adc/st,stm32-adc.txt | 5 +++++
> > 1 file changed, 5 insertions(+)
>
> Acked-by: Rob Herring <robh@xxxxxxxxxx>
Applied to the togreg branch of iio.git and pushed out as testings.
Thanks for review Rob and thanks for the patch Fabrice.
Jonathan
> --
> To unsubscribe from this list: send the line "unsubscribe linux-iio" in
> the body of a message to majordomo@xxxxxxxxxxxxxxx
> More majordomo info at http://vger.kernel.org/majordomo-info.html