Re: [PATCH] iio: imu: adis16480: Fix acceleration scale factor for adis16480
From: Jonathan Cameron
Date: Wed Aug 09 2017 - 10:38:56 EST
On Fri, 4 Aug 2017 05:49:32 +0200
Lars-Peter Clausen <lars@xxxxxxxxxx> wrote:
> On 08/04/2017 12:37 AM, Dragos Bogdan wrote:
> > According to the datasheet, the range of the acceleration is [-10 g, + 10 g],
> > so the scale factor should be 10 instead of 5.
> >
> > Signed-off-by: Dragos Bogdan <dragos.bogdan@xxxxxxxxxx>
>
> Acked-by: Lars-Peter Clausen <lars@xxxxxxxxxx>
>
> Thanks.
Applied to the fixes-togreg branch of iio.git and marked for stable.
Thanks,
Jonathan
>
> > ---
> > drivers/iio/imu/adis16480.c | 2 +-
> > 1 file changed, 1 insertion(+), 1 deletion(-)
> >
> > diff --git a/drivers/iio/imu/adis16480.c b/drivers/iio/imu/adis16480.c
> > index 8cf84d3488b2..12898424d838 100644
> > --- a/drivers/iio/imu/adis16480.c
> > +++ b/drivers/iio/imu/adis16480.c
> > @@ -696,7 +696,7 @@ static const struct adis16480_chip_info adis16480_chip_info[] = {
> > .gyro_max_val = IIO_RAD_TO_DEGREE(22500),
> > .gyro_max_scale = 450,
> > .accel_max_val = IIO_M_S_2_TO_G(12500),
> > - .accel_max_scale = 5,
> > + .accel_max_scale = 10,
> > },
> > [ADIS16485] = {
> > .channels = adis16485_channels,
> >
>