[PATCH] reset: sunxi: fix number of reset lines

From: Philipp Zabel
Date: Fri Aug 11 2017 - 06:40:34 EST


The Allwinner reset controller has 32-bit registers, but resource_size
is measured in bytes, not number of registers.

Signed-off-by: Philipp Zabel <p.zabel@xxxxxxxxxxxxxx>
---
drivers/reset/reset-sunxi.c | 4 ++--
1 file changed, 2 insertions(+), 2 deletions(-)

diff --git a/drivers/reset/reset-sunxi.c b/drivers/reset/reset-sunxi.c
index cd585cd2f04dd..2c7dd1fd08df6 100644
--- a/drivers/reset/reset-sunxi.c
+++ b/drivers/reset/reset-sunxi.c
@@ -107,7 +107,7 @@ static int sunxi_reset_init(struct device_node *np)
spin_lock_init(&data->lock);

data->rcdev.owner = THIS_MODULE;
- data->rcdev.nr_resets = size * 32;
+ data->rcdev.nr_resets = size * 8;
data->rcdev.ops = &sunxi_reset_ops;
data->rcdev.of_node = np;

@@ -162,7 +162,7 @@ static int sunxi_reset_probe(struct platform_device *pdev)
spin_lock_init(&data->lock);

data->rcdev.owner = THIS_MODULE;
- data->rcdev.nr_resets = resource_size(res) * 32;
+ data->rcdev.nr_resets = resource_size(res) * 8;
data->rcdev.ops = &sunxi_reset_ops;
data->rcdev.of_node = pdev->dev.of_node;

--
2.11.0