Re: [PATCH] ASoC: mediatek: Correct the interrupt property
From: Rob Herring
Date: Thu Aug 17 2017 - 17:20:01 EST
On Tue, Aug 15, 2017 at 09:51:40PM +0800, Ryder Lee wrote:
> On Tue, 2017-08-15 at 12:53 +0100, Mark Brown wrote:
> > On Tue, Aug 15, 2017 at 04:07:02PM +0800, Ryder Lee wrote:
> >
> > > This patch update interrupt property since we only use ASYS IRQ
> > > in the driver, and this may confuse people.
> >
> > > - interrupts = <GIC_SPI 104 IRQ_TYPE_LEVEL_LOW>,
> > > - <GIC_SPI 132 IRQ_TYPE_LEVEL_LOW>;
> > > + interrupts = <GIC_SPI 132 IRQ_TYPE_LEVEL_LOW>;
> >
> > What harm does having the extra information in the bindings do? If it's
> > possible there might be a use for the extra interrupt it seems better to
> > have people describe it.
Agreed. It should describe interrupts the h/w has, not what the driver
(currently) uses.
>
> Yes you're right. The current driver get IRQ number by index "0" but
> actually it should be "1" (GIC 132). Perhaps we can switch to use the
> platform_get_irq_byname() and add interrupt-name in DT so that binding
> can be agnostic of the IRQ order.
The binding is wrong already in that it says a single interrrupt. The
example has 2 though. Add the 2nd interrupt and define the order such
that you don't break the current driver. Probably that means ASYS is
first.
Rob