[PATCH net-next] net: hns3: Fixes the wrong IS_ERR check on the returned phydev value
From: Salil Mehta
Date: Wed Aug 30 2017 - 07:06:41 EST
This patch removes the wrong check being done for the phy device being
returned by the mdiobus_get_phy() function. This function never returns
the error pointers.
Fixes: 256727da7395 ("net: hns3: Add MDIO support to HNS3 Ethernet
Driver for hip08 SoC")
Reported-by: Dan Carpenter <dan.carpenter@xxxxxxxxxx>
Signed-off-by: Salil Mehta <salil.mehta@xxxxxxxxxx>
---
drivers/net/ethernet/hisilicon/hns3/hns3pf/hclge_mdio.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/net/ethernet/hisilicon/hns3/hns3pf/hclge_mdio.c b/drivers/net/ethernet/hisilicon/hns3/hns3pf/hclge_mdio.c
index a2add8b..f32d719 100644
--- a/drivers/net/ethernet/hisilicon/hns3/hns3pf/hclge_mdio.c
+++ b/drivers/net/ethernet/hisilicon/hns3/hns3pf/hclge_mdio.c
@@ -150,7 +150,7 @@ int hclge_mac_mdio_config(struct hclge_dev *hdev)
}
phydev = mdiobus_get_phy(mdio_bus, mac->phy_addr);
- if (!phydev || IS_ERR(phydev)) {
+ if (!phydev) {
dev_err(mdio_bus->parent, "Failed to get phy device\n");
mdiobus_unregister(mdio_bus);
return -EIO;
--
2.7.4