Re: [mainline][DLPAR][Oops] OF: ERROR: Bad of_node_put() on /cpus
From: Michael Ellerman
Date: Wed Sep 20 2017 - 07:39:17 EST
Rob Herring <robh@xxxxxxxxxx> writes:
> On Fri, Sep 15, 2017 at 6:04 AM, abdul <abdhalee@xxxxxxxxxxxxxxxxxx> wrote:
>> Hi,
>>
>> Mainline kernel panics during DLPAR CPU add/remove operation.
>>
>> Machine Type: Power8 PowerVM LPAR
>> kernel 4.13.0
>
> Did 4.12 work or when was it last working? I'm not seeing anything
> recent in the DT code that looks suspicious.
I'm pretty sure it's:
int dlpar_attach_node(struct device_node *dn, struct device_node *parent)
{
int rc;
dn->parent = parent;
rc = of_attach_node(dn);
if (rc) {
printk(KERN_ERR "Failed to add device node %pOF\n", dn);
return rc;
}
of_node_put(dn->parent);
HERE ^^^^^^^^^^
return 0;
}
Prior to 215ee763f8cb ("powerpc: pseries: remove dlpar_attach_node
dependency on full path"), we re-looked up the parent, and got another
reference on it. That meant the put before the return there was correct.
But now it's not because the caller has a reference to parent but it's
not ours to drop.
Testing a fix, will report back.
cheers