[PATCH v2 1/2] ARM: dts: Fix I2C repeated start issue on Armada-38x

From: Kalyan Kinthada
Date: Thu Sep 28 2017 - 17:36:41 EST


All the Armada 38x(380, 385, 388) have a silicon issue in
the I2C controller which violates the I2C repeated start timing
(errata FE-8471889).

i2c-mv64xxx driver handles this errata based on the compatible string
"marvell,mv78230-a0-i2c".

This patch activates the "marvell,mv78230-a0-i2c" compatible string
for the I2C controller on armada-38x SoC based devices.

Signed-off-by: Kalyan Kinthada <kalyan.kinthada@xxxxxxxxxxxxxxxxxxx>
---
arch/arm/boot/dts/armada-38x.dtsi | 4 ++--
1 file changed, 2 insertions(+), 2 deletions(-)

diff --git a/arch/arm/boot/dts/armada-38x.dtsi b/arch/arm/boot/dts/armada-38x.dtsi
index 7ff0811e61db..4960722aab32 100644
--- a/arch/arm/boot/dts/armada-38x.dtsi
+++ b/arch/arm/boot/dts/armada-38x.dtsi
@@ -178,7 +178,7 @@
};

i2c0: i2c@11000 {
- compatible = "marvell,mv64xxx-i2c";
+ compatible = "marvell,mv78230-a0-i2c", "marvell,mv64xxx-i2c";
reg = <0x11000 0x20>;
#address-cells = <1>;
#size-cells = <0>;
@@ -189,7 +189,7 @@
};

i2c1: i2c@11100 {
- compatible = "marvell,mv64xxx-i2c";
+ compatible = "marvell,mv78230-a0-i2c", "marvell,mv64xxx-i2c";
reg = <0x11100 0x20>;
#address-cells = <1>;
#size-cells = <0>;
--
2.14.1