[Patch 3/6] ARM: OMAP: DRA7xx: Make CAM clock domain SWSUP only
From: Benoit Parrot
Date: Thu Oct 12 2017 - 15:28:22 EST
HWSUP on this domain is only working when VIP1 probes.
If only VIP2 on DRA74x or CAL on DRA72x probes the domain does
not get enabled. This might indicates an issue in the HW Auto
state-machine for this domain.
Work around is to set the CAM domain to use SWSUP only.
Signed-off-by: Benoit Parrot <bparrot@xxxxxx>
---
arch/arm/mach-omap2/clockdomains7xx_data.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/arch/arm/mach-omap2/clockdomains7xx_data.c b/arch/arm/mach-omap2/clockdomains7xx_data.c
index 67ebff829cf2..dd37efa2c652 100644
--- a/arch/arm/mach-omap2/clockdomains7xx_data.c
+++ b/arch/arm/mach-omap2/clockdomains7xx_data.c
@@ -609,7 +609,7 @@ static struct clockdomain cam_7xx_clkdm = {
.dep_bit = DRA7XX_CAM_STATDEP_SHIFT,
.wkdep_srcs = cam_wkup_sleep_deps,
.sleepdep_srcs = cam_wkup_sleep_deps,
- .flags = CLKDM_CAN_HWSUP_SWSUP,
+ .flags = CLKDM_CAN_SWSUP,
};
static struct clockdomain l4per_7xx_clkdm = {
--
2.9.0