Re: Lowering the log level in watchdog_dev_register when err==-EBUSY

From: Guenter Roeck
Date: Thu Oct 12 2017 - 15:54:10 EST


On Thu, Oct 12, 2017 at 07:15:59PM +0100, Radu Rendec wrote:
> On Wed, 2017-10-11 at 11:46 -0700, Guenter Roeck wrote:
> > On Wed, Oct 11, 2017 at 06:46:31PM +0100, Radu Rendec wrote:
> > > In a project I'm working on we have a valid use case where we activate
> > > both the i6300esb and softdog watchdogs. We always activate i6300esb
> > > first (which uses the "legacy" watchdog API) and then softdog. This
> > > gets us two "error" level messages (coming from watchdog_cdev_register)
> > > although softdog falls back to the "new" API and registers its char
> > > device just fine.
> > >
> > > Since watchdog_cdev_register/watchdog_dev_register seem to be used only
> > > by watchdog_register_device and the latter always falls back to the
> > > "new" API, I'm thinking about lowering the log level of these messages
> > > when err is -EBUSY.
> >
> > I would suggest to convert the offending driver to use the watchdog subsystem
> > (and along the line remove the restriction of only supporting a single
> > instance). You have the hardware, so that should be a straightforward change.
>
> Thanks for the suggestion! That makes sense. I will start working on
> converting i6300esb and submit a patch in a few days.
>
> By the way, I don't have the hardware. I'm using it with KVM (Qemu),
> but I guess that's good enough since I'm not going to touch any of the
> code parts that deal with the hardware.
>
Ah, interesting. Can you send me the qemu command line ?

Thanks,
Guenter