Re: [PATCH] mac80211: aggregation: Convert timers to use timer_setup()
From: Kees Cook
Date: Wed Oct 18 2017 - 10:19:12 EST
On Wed, Oct 18, 2017 at 3:29 AM, Johannes Berg
<johannes@xxxxxxxxxxxxxxxx> wrote:
>> This has been the least trivial timer conversion yet. Given the use of
>> RCU and other things I may not even know about, I'd love to get a close
>> look at this. I *think* this is correct, as it will re-lookup the tid
>> entries when firing the timer.
>
> I'm not really sure why you're doing the lookup again? That seems
> pointless, since you already have the right structure, and already rely
> on it being valid. You can't really get a new struct assigned to the
> same TID without the old one being destroyed.
I couldn't tell what the lifetime expectation was, so I left the
re-lookup. I assumed it was possible to have a timer fire after the
structure had been removed from the station structure.
-Kees
--
Kees Cook
Pixel Security