[PATCH v2 01/10] dt-bindings: fix the binding of Allwinner DE2 CCU of A83T and H3
From: Icenowy Zheng
Date: Fri Oct 27 2017 - 11:08:58 EST
The DE2 CCU is different on A83T and H3 -- the parent of the clocks on
A83T is PLL_DE but on H3 it's the DE module clock. This is not noticed
when I develop the DE2 CCU driver.
Fix the binding by using different compatibles for A83T and H3, adding
notes for the PLL_DE usage on A83T, and change the binding example's
compatible from A83T to H3 (as it specifies the DE module clock).
Fixes: ed74f8a8a679 ("dt-bindings: add binding for the Allwinner DE2 CCU")
Signed-off-by: Icenowy Zheng <icenowy@xxxxxxx>
---
Documentation/devicetree/bindings/clock/sun8i-de2.txt | 5 +++--
1 file changed, 3 insertions(+), 2 deletions(-)
diff --git a/Documentation/devicetree/bindings/clock/sun8i-de2.txt b/Documentation/devicetree/bindings/clock/sun8i-de2.txt
index 631d27cd89d6..f2fa87c4765c 100644
--- a/Documentation/devicetree/bindings/clock/sun8i-de2.txt
+++ b/Documentation/devicetree/bindings/clock/sun8i-de2.txt
@@ -4,13 +4,14 @@ Allwinner Display Engine 2.0 Clock Control Binding
Required properties :
- compatible: must contain one of the following compatibles:
- "allwinner,sun8i-a83t-de2-clk"
+ - "allwinner,sun8i-h3-de2-clk"
- "allwinner,sun8i-v3s-de2-clk"
- "allwinner,sun50i-h5-de2-clk"
- reg: Must contain the registers base address and length
- clocks: phandle to the clocks feeding the display engine subsystem.
Three are needed:
- - "mod": the display engine module clock
+ - "mod": the display engine module clock (on A83T it's the DE PLL)
- "bus": the bus clock for the whole display engine subsystem
- clock-names: Must contain the clock names described just above
- resets: phandle to the reset control for the display engine subsystem.
@@ -19,7 +20,7 @@ Required properties :
Example:
de2_clocks: clock@1000000 {
- compatible = "allwinner,sun8i-a83t-de2-clk";
+ compatible = "allwinner,sun8i-h3-de2-clk";
reg = <0x01000000 0x100000>;
clocks = <&ccu CLK_BUS_DE>,
<&ccu CLK_DE>;
--
2.13.6