Re: [PATCH 1/2] serial: 8250_fintek: Return -EINVAL on invalid configuration
From: Ricardo Ribalda Delgado
Date: Wed Nov 22 2017 - 17:31:07 EST
ping?
On Mon, Nov 6, 2017 at 11:49 AM, Ricardo Ribalda Delgado
<ricardo.ribalda@xxxxxxxxx> wrote:
> Hardware does not support having the same RTS level during RX and TX
> when RS485 mode is on (URA in Fintek terminology).
>
> The manufacturer has also confirmed that the delays are not enabled if
> the RS485 mode is not enabled.
>
> Therefore we should return -EINVAL if the user wants to have the same
> value for RTS_ON_SEND and RTS_AFTER_SEND.
>
> Cc: "Ji-Ze Hong (Peter Hong)" <hpeter@xxxxxxxxx>
> Cc: Lukas Wunner <lukas@xxxxxxxxx>
> Signed-off-by: Ricardo Ribalda Delgado <ricardo.ribalda@xxxxxxxxx>
> ---
> drivers/tty/serial/8250/8250_fintek.c | 17 +++++++++--------
> 1 file changed, 9 insertions(+), 8 deletions(-)
>
> diff --git a/drivers/tty/serial/8250/8250_fintek.c b/drivers/tty/serial/8250/8250_fintek.c
> index c41cbb52f1fe..ca7e96f9f080 100644
> --- a/drivers/tty/serial/8250/8250_fintek.c
> +++ b/drivers/tty/serial/8250/8250_fintek.c
> @@ -201,10 +201,17 @@ static int fintek_8250_rs485_config(struct uart_port *port,
> if (!pdata)
> return -EINVAL;
>
> - if (rs485->flags & SER_RS485_ENABLED)
> + /* Hardware do not support same RTS level on send and receive */
> + if (!(rs485->flags & SER_RS485_RTS_ON_SEND) ==
> + !(rs485->flags & SER_RS485_RTS_AFTER_SEND))
> + return -EINVAL;
> +
> + if (rs485->flags & SER_RS485_ENABLED) {
> memset(rs485->padding, 0, sizeof(rs485->padding));
> - else
> + config |= RS485_URA;
> + } else {
> memset(rs485, 0, sizeof(*rs485));
> + }
>
> rs485->flags &= SER_RS485_ENABLED | SER_RS485_RTS_ON_SEND |
> SER_RS485_RTS_AFTER_SEND;
> @@ -219,12 +226,6 @@ static int fintek_8250_rs485_config(struct uart_port *port,
> config |= RXW4C_IRA;
> }
>
> - if ((!!(rs485->flags & SER_RS485_RTS_ON_SEND)) ==
> - (!!(rs485->flags & SER_RS485_RTS_AFTER_SEND)))
> - rs485->flags &= ~SER_RS485_ENABLED;
> - else
> - config |= RS485_URA;
> -
> if (rs485->flags & SER_RS485_RTS_ON_SEND)
> config |= RTS_INVERT;
>
> --
> 2.14.2
>
--
Ricardo Ribalda