[PATCH net-next v5 3/4] net: phy: smsc: LAN8710/20: add PHY_RST_AFTER_CLK_EN flag

From: Richard Leitner
Date: Mon Dec 11 2017 - 07:17:47 EST


From: Richard Leitner <richard.leitner@xxxxxxxxxxx>

The Microchip/SMSC LAN8710/LAN8720 PHYs need (according to their
datasheet [1]) a continuous REF_CLK when configured to "REF_CLK In Mode".
Therefore set the PHY_RST_AFTER_CLK_EN flag for those PHYs to let the
ETH driver reset them after the REF_CLK is enabled.

[1] http://ww1.microchip.com/downloads/en/DeviceDoc/00002165B.pdf

Signed-off-by: Richard Leitner <richard.leitner@xxxxxxxxxxx>
Reviewed-by: Andrew Lunn <andrew@xxxxxxx>
---
drivers/net/phy/smsc.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/drivers/net/phy/smsc.c b/drivers/net/phy/smsc.c
index a1961ba87e2b..be399d645224 100644
--- a/drivers/net/phy/smsc.c
+++ b/drivers/net/phy/smsc.c
@@ -312,7 +312,7 @@ static struct phy_driver smsc_phy_driver[] = {
.name = "SMSC LAN8710/LAN8720",

.features = PHY_BASIC_FEATURES,
- .flags = PHY_HAS_INTERRUPT,
+ .flags = PHY_HAS_INTERRUPT | PHY_RST_AFTER_CLK_EN,

.probe = smsc_phy_probe,

--
2.11.0