Re: [PATCH net-next v5 1/4] phylib: Add device reset delay support

From: Andrew Lunn
Date: Mon Dec 11 2017 - 08:41:02 EST


On Mon, Dec 11, 2017 at 01:16:57PM +0100, Richard Leitner wrote:
> From: Richard Leitner <richard.leitner@xxxxxxxxxxx>
>
> Some PHYs need a minimum time after the reset gpio was asserted and/or
> deasserted. To ensure we meet these timing requirements add two new
> optional devicetree parameters for the phy: reset-delay-us and
> reset-post-delay-us.
>
> Signed-off-by: Richard Leitner <richard.leitner@xxxxxxxxxxx>
> Reviewed-by: Geert Uytterhoeven <geert+renesas@xxxxxxxxx>

Reviewed-by: Andrew Lunn <andrew@xxxxxxx>

Andrew