[PATCH v4 1/9] dt-bindings: media: Add Renesas CEU bindings
From: Jacopo Mondi
Date: Tue Jan 09 2018 - 11:26:14 EST
Add bindings documentation for Renesas Capture Engine Unit (CEU).
Signed-off-by: Jacopo Mondi <jacopo+renesas@xxxxxxxxxx>
---
.../devicetree/bindings/media/renesas,ceu.txt | 81 ++++++++++++++++++++++
1 file changed, 81 insertions(+)
create mode 100644 Documentation/devicetree/bindings/media/renesas,ceu.txt
diff --git a/Documentation/devicetree/bindings/media/renesas,ceu.txt b/Documentation/devicetree/bindings/media/renesas,ceu.txt
new file mode 100644
index 0000000..590ee27
--- /dev/null
+++ b/Documentation/devicetree/bindings/media/renesas,ceu.txt
@@ -0,0 +1,81 @@
+Renesas Capture Engine Unit (CEU)
+----------------------------------------------
+
+The Capture Engine Unit is the image capture interface found in the Renesas
+SH Mobile and RZ SoCs.
+
+The interface supports a single parallel input with data bus width of 8 or 16
+bits.
+
+Required properties:
+- compatible: Shall be "renesas,r7s72100-ceu" for CEU units found in RZ/A1-H
+ and RZ/A1-M SoCs.
+- reg: Registers address base and size.
+- interrupts: The interrupt specifier.
+
+The CEU supports a single parallel input and should contain a single 'port'
+subnode with a single 'endpoint'. Connection to input devices are modeled
+according to the video interfaces OF bindings specified in:
+Documentation/devicetree/bindings/media/video-interfaces.txt
+
+Optional endpoint properties applicable to parallel input bus described in
+the above mentioned "video-interfaces.txt" file are supported.
+
+- hsync-active: Active state of the HSYNC signal, 0/1 for LOW/HIGH respectively.
+ If property is not present, default is active high.
+- vsync-active: Active state of the VSYNC signal, 0/1 for LOW/HIGH respectively.
+ If property is not present, default is active high.
+
+Example:
+
+The example describes the connection between the Capture Engine Unit and an
+OV7670 image sensor connected to i2c1 interface.
+
+ceu: ceu@e8210000 {
+ reg = <0xe8210000 0x209c>;
+ compatible = "renesas,r7s72100-ceu";
+ interrupts = <GIC_SPI 332 IRQ_TYPE_LEVEL_HIGH>;
+
+ pinctrl-names = "default";
+ pinctrl-0 = <&vio_pins>;
+
+ status = "okay";
+
+ port {
+ ceu_in: endpoint {
+ remote-endpoint = <&ov7670_out>;
+
+ hsync-active = <1>;
+ vsync-active = <0>;
+ };
+ };
+};
+
+i2c1: i2c@fcfee400 {
+ pinctrl-names = "default";
+ pinctrl-0 = <&i2c1_pins>;
+
+ status = "okay";
+
+ clock-frequency = <100000>;
+
+ ov7670: camera@21 {
+ compatible = "ovti,ov7670";
+ reg = <0x21>;
+
+ pinctrl-names = "default";
+ pinctrl-0 = <&vio_pins>;
+
+ reset-gpios = <&port3 11 GPIO_ACTIVE_LOW>;
+ powerdown-gpios = <&port3 12 GPIO_ACTIVE_HIGH>;
+
+ port {
+ ov7670_out: endpoint {
+ remote-endpoint = <&ceu_in>;
+
+ hsync-active = <1>;
+ vsync-active = <0>;
+ };
+ };
+ };
+};
--
2.7.4