Re: [PATCH v5 02/44] clk: davinci: New driver for davinci PLL clocks

From: David Lechner
Date: Fri Jan 12 2018 - 20:11:33 EST


On 01/12/2018 10:18 AM, Sekhar Nori wrote:
On Friday 12 January 2018 08:55 PM, David Lechner wrote:

PLL output on DA850 must never be below 300MHz or above 600MHz (see
datasheet table "Allowed PLL Operating Conditions"). Does this take care
of that? Thats one of the main reasons I recall I went with some
specific values of prediv, pllm and post div in
arch/arm/mach-davinci/da850.c

Apparently, I missed this requirement. It looks like I am going to have to
rework things so that there is some coordination between the PLL and the
PLLDIV clocks in order to get the < 300MHz operating points.

Just to make sure we are on the same page. The datasheet
constraint is 600 >= PLLOUT >= 300. PLLOUT is output of POSTDIV.

Hmm... I am on a different page. It looks to me like PLLOUT is the output
of PLLM, not POSTDIV. The datasheet says nothing at all and the TRM does
not say it explicitly, but footnote 2 on the table "System PLLC Output
Clocks", for example, makes it pretty clear.


The operating points are defined in terms of ARM frequency (and
voltage). The OPPs defined in kernel today are here:
https://git.kernel.org/pub/scm/linux/kernel/git/nsekhar/linux-davinci.git/tree/arch/arm/mach-davinci/da850.c#n1092

Thanks,