Re: [PATCH v10 01/27] mm, powerpc, x86: define VM_PKEY_BITx bits if CONFIG_ARCH_HAS_PKEYS is enabled

From: Aneesh Kumar K.V
Date: Sun Jan 21 2018 - 10:34:37 EST


Ram Pai <linuxram@xxxxxxxxxx> writes:

> VM_PKEY_BITx are defined only if CONFIG_X86_INTEL_MEMORY_PROTECTION_KEYS
> is enabled. Powerpc also needs these bits. Hence lets define the
> VM_PKEY_BITx bits for any architecture that enables
> CONFIG_ARCH_HAS_PKEYS.
>

Reviewed-by: Aneesh Kumar K.V <aneesh.kumar@xxxxxxxxxxxxxxxxxx>

> Signed-off-by: Ram Pai <linuxram@xxxxxxxxxx>
> ---
> fs/proc/task_mmu.c | 4 ++--
> include/linux/mm.h | 9 +++++----
> 2 files changed, 7 insertions(+), 6 deletions(-)
>
> diff --git a/fs/proc/task_mmu.c b/fs/proc/task_mmu.c
> index 339e4c1..b139617 100644
> --- a/fs/proc/task_mmu.c
> +++ b/fs/proc/task_mmu.c
> @@ -674,13 +674,13 @@ static void show_smap_vma_flags(struct seq_file *m, struct vm_area_struct *vma)
> [ilog2(VM_MERGEABLE)] = "mg",
> [ilog2(VM_UFFD_MISSING)]= "um",
> [ilog2(VM_UFFD_WP)] = "uw",
> -#ifdef CONFIG_X86_INTEL_MEMORY_PROTECTION_KEYS
> +#ifdef CONFIG_ARCH_HAS_PKEYS
> /* These come out via ProtectionKey: */
> [ilog2(VM_PKEY_BIT0)] = "",
> [ilog2(VM_PKEY_BIT1)] = "",
> [ilog2(VM_PKEY_BIT2)] = "",
> [ilog2(VM_PKEY_BIT3)] = "",
> -#endif
> +#endif /* CONFIG_ARCH_HAS_PKEYS */
> };
> size_t i;
>
> diff --git a/include/linux/mm.h b/include/linux/mm.h
> index ea818ff..01381d3 100644
> --- a/include/linux/mm.h
> +++ b/include/linux/mm.h
> @@ -228,15 +228,16 @@ extern int overcommit_kbytes_handler(struct ctl_table *, int, void __user *,
> #define VM_HIGH_ARCH_4 BIT(VM_HIGH_ARCH_BIT_4)
> #endif /* CONFIG_ARCH_USES_HIGH_VMA_FLAGS */
>
> -#if defined(CONFIG_X86)
> -# define VM_PAT VM_ARCH_1 /* PAT reserves whole VMA at once (x86) */
> -#if defined (CONFIG_X86_INTEL_MEMORY_PROTECTION_KEYS)
> +#ifdef CONFIG_ARCH_HAS_PKEYS
> # define VM_PKEY_SHIFT VM_HIGH_ARCH_BIT_0
> # define VM_PKEY_BIT0 VM_HIGH_ARCH_0 /* A protection key is a 4-bit value */
> # define VM_PKEY_BIT1 VM_HIGH_ARCH_1
> # define VM_PKEY_BIT2 VM_HIGH_ARCH_2
> # define VM_PKEY_BIT3 VM_HIGH_ARCH_3
> -#endif
> +#endif /* CONFIG_ARCH_HAS_PKEYS */
> +
> +#if defined(CONFIG_X86)
> +# define VM_PAT VM_ARCH_1 /* PAT reserves whole VMA at once (x86) */
> #elif defined(CONFIG_PPC)
> # define VM_SAO VM_ARCH_1 /* Strong Access Ordering (powerpc) */
> #elif defined(CONFIG_PARISC)
> --
> 1.7.1
>
> --
> To unsubscribe, send a message with 'unsubscribe linux-mm' in
> the body to majordomo@xxxxxxxxxx For more info on Linux MM,
> see: http://www.linux-mm.org/ .
> Don't email: <a href=mailto:"dont@xxxxxxxxx";> email@xxxxxxxxx </a>