Hi Randy,
On 01/22/2018 09:18 AM, Randy Li wrote:
Also the power domain driver could manage the clocks as well, I would
suggest to use pm_runtime_*.
actually the clocks required by pm domain may not be the same as what we
want to control here, there might be some clocks only be needed when
accessing mmu registers.