[PATCH 2/2] net/ibm/emac: wrong bit is used for STA control register write

From: Ivan Mikhaylov
Date: Mon Jan 22 2018 - 11:01:16 EST


STA control register has areas of mode and opcodes for opeations. 18 bit is
using for mode selection, where 0 is old MIO/MDIO access method and 1 is
indirect access mode. 19-20 bits are using for setting up read/write
operation(STA opcodes). In current state 'read' is set into old MIO/MDIO mode
with 19 bit and write operation is set into 18 bit which is mode selection,
not a write operation. To correlate write with read we set it into 20 bit.

Signed-off-by: Ivan Mikhaylov <ivan@xxxxxxxxxx>
---
drivers/net/ethernet/ibm/emac/emac.h | 2 +-
1 files changed, 1 insertions(+), 1 deletions(-)

diff --git a/drivers/net/ethernet/ibm/emac/emac.h b/drivers/net/ethernet/ibm/emac/emac.h
index d0a0e3b..c26d263 100644
--- a/drivers/net/ethernet/ibm/emac/emac.h
+++ b/drivers/net/ethernet/ibm/emac/emac.h
@@ -244,7 +244,7 @@ struct emac_regs {
#define EMAC_STACR_PHYE 0x00004000
#define EMAC_STACR_STAC_MASK 0x00003000
#define EMAC_STACR_STAC_READ 0x00001000
-#define EMAC_STACR_STAC_WRITE 0x00002000
+#define EMAC_STACR_STAC_WRITE 0x00000800
#define EMAC_STACR_OPBC_MASK 0x00000C00
#define EMAC_STACR_OPBC_50 0x00000000
#define EMAC_STACR_OPBC_66 0x00000400
--
1.7.1