[PATCHv1] dt-bindings: misc: add Intel Stratix10 service layer binding
From: richard . gong
Date: Tue Jan 23 2018 - 14:23:22 EST
From: Richard Gong <richard.gong@xxxxxxxxx>
Add a device tree binding for the Intel Stratix10 service layer driver
Signed-off-by: Richard Gong <richard.gong@xxxxxxxxx>
---
.../devicetree/bindings/misc/intel-service.txt | 56 ++++++++++++++++++++++
1 file changed, 56 insertions(+)
create mode 100644 Documentation/devicetree/bindings/misc/intel-service.txt
diff --git a/Documentation/devicetree/bindings/misc/intel-service.txt b/Documentation/devicetree/bindings/misc/intel-service.txt
new file mode 100644
index 0000000..254e4a1
--- /dev/null
+++ b/Documentation/devicetree/bindings/misc/intel-service.txt
@@ -0,0 +1,56 @@
+Intel Service Layer Driver for Stratix10 SoC
+============================================
+Intel Stratix10 SoC is composed of a 64 bit quad-core ARM Cortex A53 hard
+processor system (HPS) and Secure Device Manager (SDM). When the FPGA is
+configured from HPS, there needs to be a way for HPS to notify SDM the
+location and size of the configuration data. Then SDM will get the
+configuration data from that location and perform the FPGA configuration.
+
+To meet the whole system security needs and support virtual machine requesting
+communication with SDM, only the secure world of software (EL3, Exception
+Layer 3) can interface with SDM. All software entities running on other
+exception layers must channel through the EL3 software whenever it needs
+service from SDM.
+
+Intel Stratix10 service layer driver, running at privileged exception level
+(EL1, Exception Layer 1), interfaces with the service providers and provides
+the services for FPGA configuration, QSPI, Crypto and warm reset. Service layer
+driver also manages secure monitor call (SMC) to communicate with secure monitor
+code running in EL3.
+
+Required properties:
+--------------------
+The following are the mandatory properties:
+
+- compatible:
+ "intc,svc-1.0"
+- method:
+ smc or hvc
+ smc - Secure Monitor Call
+ hvc - Hypervisor Call
+- memory-region:
+ phandle to the reserved memory node. See
+ Documentation/devicetree/bindings/reserved-memory/reserved-memory.txt
+ for details
+
+Example:
+--------
+
+ reserved-memory {
+ #address-cells = <2>;
+ #size-cells = <2>;
+ ranges;
+
+ service_reserved: svcbuffer@0 {
+ compatible = "shared-dma-pool";
+ reg = <0x0 0x0 0x0 0x1000000>;
+ alignment = <0x1000>;
+ no-map;
+ };
+ };
+
+ svc {
+ compatible = "intc,svc-1.0";
+ method = "smc";
+ memory-region = <&service_reserved>
+ };
--
2.7.4