Re: [PATCH] soc: rockchip: power-domain: remove PM clocks

From: JeffyChen
Date: Thu Mar 01 2018 - 04:09:57 EST


Hi Geert,

Thanks for your reply.

On 03/01/2018 04:33 PM, Geert Uytterhoeven wrote:
>so maybe we can:
>1/ let the device(dts) or driver decide which clock is PM clk, and add it
>using*pm_clk_add* APIs (even of_pm_clk_add_clks() if all clocks are pm clk)
>
>2/ add support for critical PM clk, which would return error to the driver
>if anything wrong
>
>3/ make sure PM clk always be controlled(otherwise it might be unexpected
>disabled by other clocks under the same clk parent?):
> a) make sure Runtime PM is always enabled. and as discussed, we can select
>PM in ARCH_ROCKCHIP
On Renesas SoCs, we only add the device's module clock with pm_clk_add().
Drivers that don't care about properties of the module clock just call
pm_runtime_*(). That way the same driver works on different SoCs using
the same device, with and without power and/or clock domains.

well, i think we may need to check:
1/ so the driver might not know is the clock really enabled(currently):

static void pm_clk_acquire(struct device *dev, struct pm_clock_entry *ce)
{
if (!ce->clk)
ce->clk = clk_get(dev, ce->con_id);
if (IS_ERR(ce->clk)) {
ce->status = PCE_STATUS_ERROR;

static inline void __pm_clk_enable(struct device *dev, struct pm_clock_entry *ce)
{
int ret;

if (ce->status < PCE_STATUS_ERROR) {
ret = clk_enable(ce->clk);
if (!ret)
ce->status = PCE_STATUS_ENABLED;

it seems the status is private.

2/ the pm_clk_resume/suspend seems only be called in the domain's suspend/resume ops(or USE_PM_CLK_RUNTIME_OPS, or called directly in the drivers for example tegra-aconnect):

# cgrep pm_clk_resume -w
./include/linux/pm_clock.h:50:extern int pm_clk_resume(struct device *dev);
./include/linux/pm_clock.h:83:#define pm_clk_resume NULL
./drivers/bus/tegra-aconnect.c:62: return pm_clk_resume(dev);
./drivers/dma/tegra210-adma.c:649: ret = pm_clk_resume(dev);
./drivers/base/power/clock_ops.c:421: * pm_clk_resume - Enable clocks in a device's PM clock list.
./drivers/base/power/clock_ops.c:424:int pm_clk_resume(struct device *dev)
./drivers/base/power/clock_ops.c:444:EXPORT_SYMBOL_GPL(pm_clk_resume);
./drivers/base/power/clock_ops.c:533: ret = pm_clk_resume(dev);
./drivers/base/power/domain.c:1685: genpd->dev_ops.start = pm_clk_resume;
./drivers/irqchip/irq-gic-pm.c:36: ret = pm_clk_resume(dev);

so if the device doesn't have a power domain, the PM clks could be unmanaged right?

by the way, the tegra drivers(tegra-aconnect/tegra210-adma) seems like good examples of using current PM clks...


but anyway, force adding all clocks as PM clks in the rockchip power domain driver seems wrong...


Drivers that care about properties of the module clock (mainly frequency)
can still use the clk_*() API for that. Other (optional) clocks must be
handled by the device driver itself.

Gr{oetje,eeting}s,

Geert

--
Geert Uytterhoeven -- There's lots of Linux beyond ia32 --geert@xxxxxxxxxxxxxx

In personal conversations with technical people, I call myself a hacker. But
when I'm talking to journalists I just say "programmer" or something like that.