[PATCH] perf vendor events: fix processing for xfs

From: John Garry
Date: Wed Mar 14 2018 - 13:11:31 EST


In the recently introduced support for vendor subdirectory,
the checking for directory entries under xfs (or any other fs
which does not support dirent.d_type) is missing the check
for links for current and parent directory. This can result
in a broken pmu_events.c being generated.

Fix this by adding the appropriate check in is_leaf_dir().

Cc: Sukadev Bhattiprolu <sukadev@xxxxxxxxxxxxxxxxxx>
Signed-off-by: John Garry <john.garry@xxxxxxxxxx>

diff --git a/tools/perf/pmu-events/jevents.c b/tools/perf/pmu-events/jevents.c
index 1c01844..db3a594 100644
--- a/tools/perf/pmu-events/jevents.c
+++ b/tools/perf/pmu-events/jevents.c
@@ -873,7 +873,10 @@ static int is_leaf_dir(const char *fpath)
return 0;

while ((dir = readdir(d)) != NULL) {
- if (dir->d_type == DT_DIR && dir->d_name[0] != '.') {
+ if (!strcmp(dir->d_name, ".") || !strcmp(dir->d_name, ".."))
+ continue;
+
+ if (dir->d_type == DT_DIR) {
res = 0;
break;
} else if (dir->d_type == DT_UNKNOWN) {
--
1.9.1