Re: [PATCH net-next 03/10] net: mvpp2: phylink support
From: Antoine Tenart
Date: Mon Mar 19 2018 - 04:45:35 EST
Hi Russell,
On Fri, Mar 16, 2018 at 04:03:22PM +0000, Russell King - ARM Linux wrote:
> On Fri, Mar 16, 2018 at 11:33:44AM +0100, Antoine Tenart wrote:
> > +static void mvpp2_phylink_validate(struct net_device *dev,
> > + unsigned long *supported,
> > + struct phylink_link_state *state)
> > +{
> > + __ETHTOOL_DECLARE_LINK_MODE_MASK(mask) = { 0, };
> > +
> > + phylink_set(mask, Autoneg);
> > + phylink_set_port_modes(mask);
> > + phylink_set(mask, Pause);
> > + phylink_set(mask, Asym_Pause);
> > +
> > + phylink_set(mask, 10baseT_Half);
> > + phylink_set(mask, 10baseT_Full);
> > + phylink_set(mask, 100baseT_Half);
> > + phylink_set(mask, 100baseT_Full);
> > + phylink_set(mask, 1000baseT_Full);
> > + phylink_set(mask, 1000baseX_Full);
>
> AFAICS, the driver (before these patches) does not support 1000baseX
> as it always clears the MVPP2_GMAC_PORT_TYPE_MASK bit, so adding this
> mode should be part of the patch adding 1000baseX support.
Right, I'll remove 1000baseX_Full from this patch and only add it in the
1000BaseX support patch.
Thanks!
Antoine
--
Antoine Ténart, Bootlin (formerly Free Electrons)
Embedded Linux and Kernel engineering
https://bootlin.com