RE: [PATCH] gpio: dwapb: Add support for 32 interrupts
From: Phil Edworthy
Date: Fri Apr 06 2018 - 06:21:03 EST
Hi Geert,
On 06 April 2018 10:57 Geert Uytterhoeven wrote:
> On Thu, Apr 5, 2018 at 11:42 AM, Phil Edworthy wrote:
> > On 30 March 2018 22:26 Andy Shevchenko wrote:
> >> On Wed, Mar 28, 2018 at 5:22 PM, Phil Edworthy wrote:
> >> > The DesignWare GPIO IP can be configured for either 1 or 32
> >> > interrupts,
> >>
> >> 1 to 32, or just a choice between two?
> > Just a choice of 1 or 32.
> > Note that by 'configured' I am talking about the hardware being
> > configured in RTL prior to manufacturing a device. Once made, you cannot
> change it.
> > This configuration affects the number of output interrupt signals from
> > the GPIO Controller block that are connected to an interrupt controller.
>
> Differentiating between different versions of an IP block using DT properties
> is usually a bad idea, for several reasons:
> - What if you discover another difference later?
> - You cannot add differentiating properties retroactively, because of
> backwards
> compatibility with old DTBS.
>
> Hence I think you should introduce a new compatible value instead.
This is not a different version of the IP, just a different configuration option.
Most IP blocks have a huge number of knobs that can be twiddled by the HW
people, such as cache size, UART fifo depth. I think this is no different.
Thanks
Phil