[PATCH 09/17] thermal: qoriq: enable/check sensor after its setup is finished

From: Bartlomiej Zolnierkiewicz
Date: Tue Apr 10 2018 - 08:44:06 EST


Enable/check sensor after enabling monitoring.

Signed-off-by: Bartlomiej Zolnierkiewicz <b.zolnierkie@xxxxxxxxxxx>
---
drivers/thermal/qoriq_thermal.c | 6 +++---
1 file changed, 3 insertions(+), 3 deletions(-)

diff --git a/drivers/thermal/qoriq_thermal.c b/drivers/thermal/qoriq_thermal.c
index cdd6f59..2695021 100644
--- a/drivers/thermal/qoriq_thermal.c
+++ b/drivers/thermal/qoriq_thermal.c
@@ -242,13 +242,13 @@ static int qoriq_tmu_probe(struct platform_device *pdev)
goto err_tmu;
}

- thermal_zone_device_toggle(data->tz, true);
- thermal_zone_device_check(data->tz);
-
/* Enable monitoring */
site |= 0x1 << (15 - data->sensor_id);
tmu_write(data, site | TMR_ME | TMR_ALPF, &data->regs->tmr);

+ thermal_zone_device_toggle(data->tz, true);
+ thermal_zone_device_check(data->tz);
+
return 0;

err_tmu:
--
1.9.1