Re: [PATCH] iio: humidity: hts221: Fix sensor reads after resume

From: Jonathan Cameron
Date: Sun May 06 2018 - 12:20:00 EST


On Mon, 30 Apr 2018 12:25:46 +0800
Shrirang Bagul <shrirang.bagul@xxxxxxxxxxxxx> wrote:

> CTRL1 register (ODR & BDU settings) gets reset after system comes back
> from suspend, causing subsequent reads from the sensor to fail.
>
> This patch restores the CTRL1 register after resume.
>
> Based on:
> git://git.kernel.org/pub/scm/linux/kernel/git/jic23/iio.git iio-fixes-for-4.14b
>
> Since 4.17.rc1, this driver uses REGMAP; I'll send a separate patch to
> address this issue.
>
> Cc: stable@xxxxxxxxxxxxxxx
> Fixes: ffebe74b7c95 (iio: humidity: hts221: avoid useless ODR reconfiguration)
Looks like part of the problem was introduced in that patch, part well predated
it (BDU).

> Signed-off-by: Shrirang Bagul <shrirang.bagul@xxxxxxxxxxxxx>
As you way, this needs to be a bit different to take into account
the change to regmap. We'll need to have that upstream before we look
at a back port. One element inline surprises me and needs further
explanation.


> ---
> drivers/iio/humidity/hts221_core.c | 12 ++++++++----
> 1 file changed, 8 insertions(+), 4 deletions(-)
>
> diff --git a/drivers/iio/humidity/hts221_core.c b/drivers/iio/humidity/hts221_core.c
> index 32524a8dc66f..fed2da64fa3b 100644
> --- a/drivers/iio/humidity/hts221_core.c
> +++ b/drivers/iio/humidity/hts221_core.c
> @@ -674,11 +674,15 @@ static int __maybe_unused hts221_resume(struct device *dev)
> struct hts221_hw *hw = iio_priv(iio_dev);
> int err = 0;
>
> - if (hw->enabled)
> - err = hts221_write_with_mask(hw, HTS221_REG_CNTRL1_ADDR,
> - HTS221_ENABLE_MASK, true);

Why drop the enable setting? Seems that we want to do this 'as well',
if the device was previous enabled.

> + err = hts221_write_with_mask(hw, HTS221_REG_CNTRL1_ADDR,
> + HTS221_BDU_MASK, 1);
> + if (err < 0)
> + goto fail_err;
>
> - return err;
> + err = hts221_update_odr(hw, hw->odr);
> +
> +fail_err:
> + return err < 0 ? err : 0;
> }
>
> const struct dev_pm_ops hts221_pm_ops = {