On Sun, May 20, 2018 at 04:26:03PM +0800, Xin Long wrote:
> On Sat, May 19, 2018 at 11:57 PM, Eric Dumazet <eric.dumazet@xxxxxxxxx> wrote:
> > SCTP experts, please take a look.
> >
> > On 05/19/2018 08:55 AM, syzbot wrote:
> >> Hello,
> >>
> >> syzbot found the following crash on:
> >>
> >> HEAD commit: 73fcb1a370c7 Merge branch 'akpm' (patches from Andrew)
> >> git tree: upstream
> >> console output: https://syzkaller.appspot.com/x/log.txt?x=1462ec0f800000
> >> kernel config: https://syzkaller.appspot.com/x/.config?x=f3b4e30da84ec1ed
> >> dashboard link: https://syzkaller.appspot.com/bug?extid=3dcd59a1f907245f891f
> >> compiler: gcc (GCC) 8.0.1 20180413 (experimental)
> >> syzkaller repro:https://syzkaller.appspot.com/x/repro.syz?x=1079cf8f800000
> Thank you.
> The Reproducer is more than helpful.
>
> setsockopt$inet_sctp6_SCTP_RTOINFO(r0, 0x84, 0x0,
> &(0x7f0000000140)={0x0, 0x6, 0x7, 0x4}, 0x10)
>
> It set rto_min=6 and rto_max=7, these are too small values.
> t3_rtx timer works fine with it. But hb_timer will get stuck there, as
> in its timer handler it starts this timer again with this value, then
> it goes to the timer handler again...
Nice, thanks Xin.
>
> HB has to repeat this and the hb timer's expire may also have to use
> 'trans->rto >> 1 ...' stuff. But we can limit the RTO's min value, like
> HZ/20, which is 'Try again later.' number used when sock lock is
> owned by others in all timer handlers.
I think a good fix for this is to not allow the application to go
below net.sctp.rto_min, and neither above net.sctp.rto_max.
Then they can even be close to each other, won't be an issue, as long
as rto_min is something sensible. Which then brings it to the second
step of a fix: to restrict rto_min to be >= HZ/5 (copying from TCP
here).