[PATCH 1/5] Documentation: DT: Add optional 'timeout-sec' property for sp805
From: Ray Jui
Date: Tue May 22 2018 - 13:54:41 EST
Update the SP805 binding document to add optional 'timeout-sec'
devicetree property
Signed-off-by: Ray Jui <ray.jui@xxxxxxxxxxxx>
Reviewed-by: Scott Branden <scott.branden@xxxxxxxxxxxx>
---
Documentation/devicetree/bindings/watchdog/sp805-wdt.txt | 2 ++
1 file changed, 2 insertions(+)
diff --git a/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt b/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt
index edc4f0e..f898a86 100644
--- a/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt
+++ b/Documentation/devicetree/bindings/watchdog/sp805-wdt.txt
@@ -19,6 +19,8 @@ Required properties:
Optional properties:
- interrupts : Should specify WDT interrupt number.
+- timeout-sec : Should specify default WDT timeout in seconds. If unset, the
+ default timeout is 30 seconds
Examples:
--