Re: [PATCH v4 0/6] mfd/regulator/clk: bd71837: ROHM BD71837 PMIC driver
From: Mark Brown
Date: Wed May 30 2018 - 11:41:43 EST
On Wed, May 30, 2018 at 03:56:34PM +0300, Matti Vaittinen wrote:
> On Wed, May 30, 2018 at 12:00:00PM +0100, Mark Brown wrote:
> > The tradeoff with forced PWM mode is that the quality of regulation will
> > be a lot better, especially if the load changes suddenly (as things like
> > CPUs often do). Most hardware that's at all current is able respond to
> > changes in load and switch modes automatically when it's appropriate,
> > except possibly in some very low power modes.
> Yes. The mode switching is automatic. But there is this control bit for
> disabling automatic mode switching and forcing the PWM. Problem with
> these 4 last bucks is just that if regulator is in PFM (and it may be
> if not forced to PWM - due to this automatic switching) then the voltage
> change is not behaving well.
That sounds like the mode switching just isn't very good and needs a bit
of help so forcing the mode is probably going to do the right thing.
Attachment:
signature.asc