Re: [PATCH 06/15] arm: dts: sun: Add missing cooling device properties for CPUs

From: Maxime Ripard
Date: Fri Jun 01 2018 - 11:17:18 EST


Hi,

On Mon, May 28, 2018 at 04:27:34PM +0530, Viresh Kumar wrote:
> On 28-05-18, 10:44, Maxime Ripard wrote:
> > Hi,
> >
> > On Fri, May 25, 2018 at 04:01:52PM +0530, Viresh Kumar wrote:
> > > The cooling device properties, like "#cooling-cells" and
> > > "dynamic-power-coefficient", should either be present for all the CPUs
> > > of a cluster or none. If these are present only for a subset of CPUs of
> > > a cluster then things will start falling apart as soon as the CPUs are
> > > brought online in a different order. For example, this will happen
> > > because the operating system looks for such properties in the CPU node
> > > it is trying to bring up, so that it can register a cooling device.
> > >
> > > Add such missing properties.
> > >
> > > Fix other missing properties (clocks, OPP, clock latency) as well to
> > > make it all work.
> > >
> > > Signed-off-by: Viresh Kumar <viresh.kumar@xxxxxxxxxx>
> >
> > The prefix should be sunxi and not sun, but it looks good to me
> > otherwise.
> >
> > Let me know what your preferred merge method is.
>
> Please pick it up directly and send it as part of your pull request.
> Do you want me to resend or can you fix the $subject ?

I just tried to apply it, and it failed. We have usually two different
PR for the H3 SoCs and the others. Could you split the H3 in a
separate patch (and fix the subject in the process?)

Thanks!
Maxime

--
Maxime Ripard, Bootlin (formerly Free Electrons)
Embedded Linux and Kernel engineering
https://bootlin.com

Attachment: signature.asc
Description: PGP signature