Re: [PATCH 3/8] serial: 8250: Copy em485 from port to real port.
From: Giulio Benetti
Date: Mon Jun 04 2018 - 06:53:10 EST
Hi,
Il 04/06/2018 12:13, Andy Shevchenko ha scritto:
On Fri, 2018-06-01 at 14:40 +0200, Giulio Benetti wrote:
em485 gets lost during serial8250_register_8250_port().
Copy em485 to final uart port.
Fixes better to go first.
I think you need to reorder the series.
Ok, thanks.
So after re-ording and clarifying TEMT interrupt, can I send v2 patchset?
Thanks
--
Giulio Benetti
CTO
MICRONOVA SRL
Sede: Via A. Niedda 3 - 35010 Vigonza (PD)
Tel. 049/8931563 - Fax 049/8931346
Cod.Fiscale - P.IVA 02663420285
Capitale Sociale â 26.000 i.v.
Iscritta al Reg. Imprese di Padova N. 02663420285
Numero R.E.A. 258642