Re: [PATCH v2 0/3] mtd: rawnand: denali: add new clocks and improve setup_data_interface

From: Boris Brezillon
Date: Thu Jun 14 2018 - 04:04:00 EST


On Thu, 14 Jun 2018 10:02:12 +0200
Richard Weinberger <richard@xxxxxxxxxxxxx> wrote:

> Am Donnerstag, 14. Juni 2018, 09:38:35 CEST schrieb Boris Brezillon:
> > On Thu, 14 Jun 2018 16:29:59 +0900
> > Masahiro Yamada <yamada.masahiro@xxxxxxxxxxxxx> wrote:
> >
> > > Hi Richard,
> > >
> > > 2018-06-14 16:25 GMT+09:00 Richard Weinberger <richard@xxxxxxxxxxxxx>:
> > > > Masahiro,
> > > >
> > > > Am Donnerstag, 14. Juni 2018, 07:11:04 CEST schrieb Masahiro Yamada:
> > > >>
> > > >> The ->setup_data_interface() hook needs to know the clock frequency.
> > > >> In fact, this IP needs three clocks, bus "which clock?" is really
> > > >> confusing. (It is not described in the DT-binding at all.)
> > > >>
> > > >> This series adds more clocks. In the new binding, three clocks
> > > >> are required: core clock, bus interface clock, ECC engine clock.
> > > >>
> > > >> This series also takes care of the backward compatibility by
> > > >> providing hardcoded values in case the new clocks are missing.
> > > >> So, existing DT should work.
> > > >>
> > > >>
> > > >> Changes in v2:
> > > >> - Split patches into sensible chunks
> > > >>
> > > >> Masahiro Yamada (3):
> > > >> mtd: rawnand: denali_dt: use dev as a shorthand of &pdev->dev
> > > >> mtd: rawnand: denali_dt: add more clocks based on IP datasheet
> > > >> mtd: rawnand: denali: optimize timing parameters for data interface
> > > >
> > > > This still means that we need to feed at least 2/3 and 3/3 into -stable to
> > > > unbreak the driver.
> > >
> > >
> > > 3/3 is not mandatory.
> > >
> > > You can only back-port 1/3 and 2/3.
> >
> > Well, patch 1 is not a fix, can we move it after patch 2 so that only
> > patch 2 is flagged with the Fixes+Cc-stable tags?
>
> Another question, shall we fix arch/arm/boot/dts/socfpga.dtsi too?

Yep.