Re: [RFC PATCH] rseq: Avoid infinite recursion when delivering SIGSEGV
From: Will Deacon
Date: Thu Jun 21 2018 - 07:52:10 EST
On Wed, Jun 20, 2018 at 12:55:35PM -0400, Mathieu Desnoyers wrote:
> ----- On Jun 20, 2018, at 12:36 PM, Will Deacon will.deacon@xxxxxxx wrote:
>
> > When delivering a signal to a task that is using rseq, we call into
> > __rseq_handle_notify_resume() so that the registers pushed in the
> > sigframe are updated to reflect the state of the restartable sequence
> > (for example, ensuring that the signal returns to the abort handler if
> > necessary).
> >
> > However, if the rseq management fails due to an unrecoverable fault when
> > accessing userspace or certain combinations of RSEQ_CS_* flags, then we
> > will attempt to deliver a SIGSEGV. This has the potential for infinite
> > recursion if the rseq code continuously fails on signal delivery.
> >
> > Avoid this problem by using force_sigsegv() instead of force_sig(), which
> > is explicitly designed to reset the SEGV handler to SIG_DFL in the case
> > of a recursive fault.
>
> Your approach looks good. One nit below implementation-wise:
Nit accepted :) v2 on its way.
Will