On Sun, Jul 01, 2018 at 07:26:20PM +0200, Saravanan Sekar wrote:
Hi ManiDuring the review of I2C controller driver, Andreas pointed out that
On 06/30/18 11:32, Manivannan Sadhasivam wrote:
Hi Saravanan,Agree, will modify the name
I agree with modifying the existing binding to accomodate other
SoC's of the same family. But the binding should be
"actions,owl-cmu.txt" since it reflects the family name.
Andreas, what do you think?sure
On Thu, Jun 28, 2018 at 09:18:05PM +0200, Saravanan Sekar wrote:
Modify clock bindings common Actions Semi Soc family S700/S900.Same as above. Should be Actions OWL SoC's Clock Management Unit (CMU).
Signed-off-by: Parthiban Nallathambi <pn@xxxxxxx>
Signed-off-by: Saravanan Sekar <sravanhome@xxxxxxxxx>
---
...tions,s900-cmu.txt => actions,sx00-cmu.txt} | 18 ++++++++++--------
1 file changed, 10 insertions(+), 8 deletions(-)
rename Documentation/devicetree/bindings/clock/{actions,s900-cmu.txt => actions,sx00-cmu.txt} (71%)
diff --git a/Documentation/devicetree/bindings/clock/actions,s900-cmu.txt b/Documentation/devicetree/bindings/clock/actions,sx00-cmu.txt
similarity index 71%
rename from Documentation/devicetree/bindings/clock/actions,s900-cmu.txt
rename to Documentation/devicetree/bindings/clock/actions,sx00-cmu.txt
index 93e4fb827cd6..8dc7edb4d198 100644
--- a/Documentation/devicetree/bindings/clock/actions,s900-cmu.txt
+++ b/Documentation/devicetree/bindings/clock/actions,sx00-cmu.txt
@@ -1,12 +1,14 @@
-* Actions S900 Clock Management Unit (CMU)
+* Actions S900/S700 Clock Management Unit (CMU)
we should use Owl instead of OWL in all places and also Actions should
be replaced by Actions Semiconductor. So, please change it in relevant
places. For this binding, title should be:
Actions Semiconductor Owl SoC's Clock Management Unit (CMU).
Thanks,
Mani
sure-The Actions S900 clock management unit generates and supplies clock to variousChange to: compatible: should be one of the following:
-controllers within the SoC. The clock binding described here is applicable to
-S900 SoC.
+The Actions S900/S700 clock management unit generates and supplies clock to
+various controllers within the SoC. The clock binding described here is
+applicable to S900/S700 SoC.
Required Properties:
-- compatible: should be "actions,s900-cmu"
+- compatible: should be one of this
Thanks,Thanks,
Mani
+ "actions,s900-cmu"
+ "actions,s700-cmu"
- reg: physical base address of the controller and length of memory mapped
region.
- clocks: Reference to the parent clocks ("hosc", "losc")
@@ -15,9 +17,9 @@ Required Properties:
Each clock is assigned an identifier, and client nodes can use this identifier
to specify the clock which they consume.
-All available clocks are defined as preprocessor macros in
-dt-bindings/clock/actions,s900-cmu.h header and can be used in device
-tree sources.
+All available clocks are defined as preprocessor macros in corresponding
+dt-bindings/clock/actions,s900-cmu.h or s700-cmu.h header and can be used in
+device tree sources.
External clocks:
--
2.18.0
Saravanan