[PATCH v2] w1: fix w1_ds2438 documentation

From: Mariusz Bialonczyk
Date: Thu Jul 05 2018 - 00:52:36 EST


The previous documentation was wrongly stating about the order
of magnitude of CONVERT_V result files contents (vad, vdd).
This commit is correcting this.

Reported-by: Adam Stolarczyk <adam@xxxxxxxxxxxxxxxxx>
Signed-off-by: Mariusz Bialonczyk <manio@xxxxxxxxxx>
---

Resending as V2 because it was malformed by mail mail app recently.
I also added the Reported-by line and added a commit message
to describe the problem (to comply with Greg's review points).

Documentation/w1/slaves/w1_ds2438 | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/Documentation/w1/slaves/w1_ds2438 b/Documentation/w1/slaves/w1_ds2438
index b99f3674c5b4..e64f65a09387 100644
--- a/Documentation/w1/slaves/w1_ds2438
+++ b/Documentation/w1/slaves/w1_ds2438
@@ -60,4 +60,4 @@ vad: general purpose A/D input (VAD)
vdd: battery input (VDD)

After the voltage conversion the value is returned as decimal ASCII.
-Note: The value is in mV, so to get a volts the value has to be divided by 10.
+Note: To get a volts the value has to be divided by 100.
--
2.18.0