[PATCH 4/5] thermal: exynos: fixed the efuse min/max value for exynos5422

From: Anand Moon
Date: Tue Jul 17 2018 - 06:13:11 EST


e-fuse range min~max range is 16~76. if e-fuse value is out of
this range, then thermal sensor may not sense thermal data properly.

CC: Bartlomiej Zolnierkiewicz <b.zolnierkie@xxxxxxxxxxx>
Signed-off-by: Anand Moon <linux.amoon@xxxxxxxxx>
---
drivers/thermal/samsung/exynos_tmu.c | 10 ++++++----
1 file changed, 6 insertions(+), 4 deletions(-)

diff --git a/drivers/thermal/samsung/exynos_tmu.c b/drivers/thermal/samsung/exynos_tmu.c
index 4a2733c..6481d91 100644
--- a/drivers/thermal/samsung/exynos_tmu.c
+++ b/drivers/thermal/samsung/exynos_tmu.c
@@ -940,11 +940,13 @@ static int exynos_map_dt_data(struct platform_device *pdev)
data->reference_voltage = 16;
data->efuse_value = 55;
if (data->soc != SOC_ARCH_EXYNOS5420 &&
- data->soc != SOC_ARCH_EXYNOS5420_TRIMINFO)
+ data->soc != SOC_ARCH_EXYNOS5420_TRIMINFO) {
+ data->min_efuse_value = 16;
+ data->max_efuse_value = 76;
+ } else {
data->min_efuse_value = 40;
- else
- data->min_efuse_value = 0;
- data->max_efuse_value = 100;
+ data->max_efuse_value = 100;
+ }
break;
case SOC_ARCH_EXYNOS5433:
data->tmu_set_trip_temp = exynos5433_tmu_set_trip_temp;
--
2.7.4