Re: [PATCH v4 1/4] rtc: omap: Cut down the shutdown time from 2 seconds to 1 sec

From: Johan Hovold
Date: Thu Jul 19 2018 - 06:23:54 EST


On Thu, Jul 12, 2018 at 10:37:37AM +0530, Keerthy wrote:
> Cut down the shutdown time from 2 seconds to 1 sec. In case of roll
> over try again.
>
> Signed-off-by: Keerthy <j-keerthy@xxxxxx>

> @@ -435,17 +435,23 @@ static void omap_rtc_power_off(void)

> + /* set alarm one second from now */
> omap_rtc_read_time_raw(rtc, &tm);
> + seconds = tm.tm_sec;
> bcd2tm(&tm);
> rtc_tm_to_time(&tm, &now);
> - rtc_time_to_tm(now + 2, &tm);
> + rtc_time_to_tm(now + 1, &tm);

One more thing, the comment before final mdelay as well as that delay
itself also needs to be updated to reflect this change.

Thanks,
Johan