[PATCH] dt-bindings: thermal: qcom-spmi-temp-alarm: Improve thermal zone in example

From: Matthias Kaehlcke
Date: Tue Jul 24 2018 - 19:50:49 EST


The current example for a thermal zone isn't very useful as reference
since it would result in a hardware shutdown at 145ÂC, instead of
allowing the system to try to shutdown gracefully. Without an ADC
channel a maximum of two trip points is useful in practice for this
sensor, with temperatures corresponding to the stage 1 and stage 2
'hardware trip points'. A critical trip point at stage 2 may allow the
system to shutdown before a hardware shutdown at stage 3 kicks in. It
should be noted though that by default the chip performs a 'partial
shutdown' when the temperature reaches stage 2, which may prevent an
orderly shutdown. The 'partial shutdown' can be disabled by software.

Signed-off-by: Matthias Kaehlcke <mka@xxxxxxxxxxxx>
---
.../bindings/thermal/qcom-spmi-temp-alarm.txt | 11 +++--------
1 file changed, 3 insertions(+), 8 deletions(-)

diff --git a/Documentation/devicetree/bindings/thermal/qcom-spmi-temp-alarm.txt b/Documentation/devicetree/bindings/thermal/qcom-spmi-temp-alarm.txt
index 290ec06fa33a..cabf813595e5 100644
--- a/Documentation/devicetree/bindings/thermal/qcom-spmi-temp-alarm.txt
+++ b/Documentation/devicetree/bindings/thermal/qcom-spmi-temp-alarm.txt
@@ -36,19 +36,14 @@ Example:
thermal-sensors = <&pm8941_temp>;

trips {
- passive {
- temperature = <1050000>;
+ stage1 {
+ temperature = <105000>;
hysteresis = <2000>;
type = "passive";
};
- alert {
+ stage2 {
temperature = <125000>;
hysteresis = <2000>;
- type = "hot";
- };
- crit {
- temperature = <145000>;
- hysteresis = <2000>;
type = "critical";
};
};
--
2.18.0.233.g985f88cf7e-goog