Re: [PATCH V1 2/3] Documentation: sdhci-msm: Add entries for passing load values
From: Rob Herring
Date: Wed Jul 25 2018 - 13:55:26 EST
On Fri, Jul 20, 2018 at 04:16:05PM +0530, Vijay Viswanath wrote:
> The load a particular sdhc controller should request from a regulator
> is device specific and hence each device should individually vote for
> the required load.
"dt-bindings: mmc: ..." for the subject.
>
> Signed-off-by: Vijay Viswanath <vviswana@xxxxxxxxxxxxxx>
> ---
> Documentation/devicetree/bindings/mmc/sdhci-msm.txt | 6 ++++++
> 1 file changed, 6 insertions(+)
>
> diff --git a/Documentation/devicetree/bindings/mmc/sdhci-msm.txt b/Documentation/devicetree/bindings/mmc/sdhci-msm.txt
> index 502b3b8..ee34f28 100644
> --- a/Documentation/devicetree/bindings/mmc/sdhci-msm.txt
> +++ b/Documentation/devicetree/bindings/mmc/sdhci-msm.txt
> @@ -26,6 +26,11 @@ Required properties:
> "cal" - reference clock for RCLK delay calibration (optional)
> "sleep" - sleep clock for RCLK delay calibration (optional)
>
> +Optional properties:
> +- <supply>-current-level - specifies load levels for supply during BUS_ON
> + and BUS_OFF states in power irq. Should be specified in
> + pairs (lpm, hpm), for BUS_OFF and BUS_ON respectively.
> + Units uA.
This should probably be a common regulator property (or maybe one exists
already).
It is missing vendor prefix and unit suffix as-is.
Rob