Re: [PATCH 01/14] thermal: ti-soc-thermal: fix TALERT IRQ handling for DRA752

From: Keerthy
Date: Fri Jul 27 2018 - 00:44:34 EST




On Wednesday 25 July 2018 07:57 PM, Bartlomiej Zolnierkiewicz wrote:
> On Wednesday, July 11, 2018 07:49:41 AM J, KEERTHY wrote:
>>
>> On 5/14/2018 5:12 PM, Bartlomiej Zolnierkiewicz wrote:
>>> .report_temperature is not set in dra752_data which
>>> results in temperature updates not being propagated by
>>> ti_bandgap_talert_irq_handler() (it doesn't make much
>>> sense to handle TALERT IRQ without reporting temperature
>>> updates to the thermal core). Fix it.
>>
>> ATM no one is using TALERT as the thermal software polls on the
>> temperature. No real benefit from TALERT.
>>
>> TALERT is set at different temperature and software polling thresholds
>> come from Device tree and i believe its best for software to go by
>> polling and then act on trip points.
>
> Could you please explain what do you mean by "no one is using
> TALERT"?
>
> The code in ti_bandgap_probe() sets TALERT thresholds and requests
> IRQ if the TI_BANDGAP_FEATURE_TALERT feature flag is set (and this
> flag is set in omap4460_data, omap4470_data, omap5430_data and
> dra752_data).

The software thresholds and the polling takes care of reducing the
temperature. What i actually meant was we never relied on talert and the
polling takes care of keeping a check on the temperature.

Regards,
Keerthy

>
> Best regards,
> --
> Bartlomiej Zolnierkiewicz
> Samsung R&D Institute Poland
> Samsung Electronics
>