Re: [PATCH v2 1/3] dt-bindings: interrupt-controller: Actions external interrupt controller
From: Manivannan Sadhasivam
Date: Mon Aug 13 2018 - 00:34:24 EST
Hi Parthiban,
On Sun, Aug 12, 2018 at 02:22:13PM +0200, Parthiban Nallathambi wrote:
> Actions Semi OWL family SoC's provides support for external interrupt
> controller to be connected and controlled using SIRQ pins. S500, S700
> and S900 provides 3 SIRQ lines and works independently for 3 external
> interrupt controllers.
>
> Signed-off-by: Parthiban Nallathambi <pn@xxxxxxx>
> Signed-off-by: Saravanan Sekar <sravanhome@xxxxxxxxx>
> ---
> .../interrupt-controller/actions,owl-sirq.txt | 46 ++++++++++++++++++++++
> 1 file changed, 46 insertions(+)
> create mode 100644 Documentation/devicetree/bindings/interrupt-controller/actions,owl-sirq.txt
>
> diff --git a/Documentation/devicetree/bindings/interrupt-controller/actions,owl-sirq.txt b/Documentation/devicetree/bindings/interrupt-controller/actions,owl-sirq.txt
> new file mode 100644
> index 000000000000..4b8437751331
> --- /dev/null
> +++ b/Documentation/devicetree/bindings/interrupt-controller/actions,owl-sirq.txt
> @@ -0,0 +1,46 @@
> +Actions Semi Owl SoCs SIRQ interrupt controller
> +
> +S500, S700 and S900 SoC's from Actions provides 3 SPI's from GIC,
> +in which external interrupt controller can be connected. 3 SPI's
> +45, 46, 47 from GIC are directly exposed as SIRQ. It has
> +the following properties:
We should really document the driver here. What it does? and how the
hierarchy is handled with GIC? etc...
> +
> +- inputs three interrupt signal from external interrupt controller
> +
> +Required properties:
> +
> +- compatible: should be "actions,owl-sirq"
> +- reg: physical base address of the controller and length of memory mapped.
...length of memory mapped region?
> +- interrupt-controller: identifies the node as an interrupt controller
> +- #interrupt-cells: specifies the number of cells needed to encode an interrupt
> + source, should be 2.
> +- actions,sirq-shared-reg: Applicable for S500 and S700 where SIRQ register
> + details are maintained at same offset/register.
> +- actions,sirq-offset: register offset for SIRQ interrupts. When registers are
> + shared, all the three offsets will be same (S500 and S700).
> +- actions,sirq-clk-sel: external interrupt controller can be either
> + connected to 32Khz or 24Mhz external/internal clock. This needs
Hertz should be specified as Hz.
> + to be configured for per SIRQ line. Failing defaults to 32Khz clock.
What value needs to be specified for selecting 24MHz clock? You should
mention the available options this property supports.
> +
> +Example for S900:
> +
> +sirq: interrupt-controller@e01b0000 {
> + compatible = "actions,owl-sirq";
> + reg = <0 0xe01b0000 0 0x1000>;
could be: reg = <0x0 0xe01b0000 0x0 0x1000>;
> + interrupt-controller;
> + #interrupt-cells = <2>;
> + actions,sirq-clk-sel = <0 0 0>;
> + actions,sirq-offset = <0x200 0x528 0x52c>;
> +};
> +
> +Example for S500 and S700:
> +
> +sirq: interrupt-controller@e01b0000 {
> + compatible = "actions,owl-sirq";
> + reg = <0 0xe01b0000 0 0x1000>;
For S500, reg base is 0xb01b0000.
Thanks
Mani
> + interrupt-controller;
> + #interrupt-cells = <2>;
> + actions,sirq-shared-reg;
> + actions,sirq-clk-sel = <0 0 0>;
> + actions,sirq-offset = <0x200 0x200 0x200>;
> +};
> --
> 2.14.4
>