[PATCH 4.14 24/29] serial: 8250_dw: always set baud rate in dw8250_set_termios

From: Greg Kroah-Hartman
Date: Tue Aug 21 2018 - 02:27:26 EST


4.14-stable review patch. If anyone has any objections, please let me know.

------------------

From: Chen Hu <hu1.chen@xxxxxxxxx>

commit dfcab6ba573445c703235ab6c83758eec12d7f28 upstream.

dw8250_set_termios() doesn't set baud rate if the arg "old ktermios" is
NULL. This happens during resume.
Call Trace:
...
[ 54.928108] dw8250_set_termios+0x162/0x170
[ 54.928114] serial8250_set_termios+0x17/0x20
[ 54.928117] uart_change_speed+0x64/0x160
[ 54.928119] uart_resume_port
...

So the baud rate is not restored after S3 and breaks the apps who use
UART, for example, console and bluetooth etc.

We address this issue by setting the baud rate irrespective of arg
"old", just like the drivers for other 8250 IPs. This is tested with
Intel Broxton platform.

Signed-off-by: Chen Hu <hu1.chen@xxxxxxxxx>
Fixes: 4e26b134bd17 ("serial: 8250_dw: clock rate handling for all ACPI platforms")
Cc: Heikki Krogerus <heikki.krogerus@xxxxxxxxxxxxxxx>
Cc: stable <stable@xxxxxxxxxxxxxxx>
Reviewed-by: Andy Shevchenko <andriy.shevchenko@xxxxxxxxxxxxxxx>
Signed-off-by: Greg Kroah-Hartman <gregkh@xxxxxxxxxxxxxxxxxxx>

---
drivers/tty/serial/8250/8250_dw.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)

--- a/drivers/tty/serial/8250/8250_dw.c
+++ b/drivers/tty/serial/8250/8250_dw.c
@@ -260,7 +260,7 @@ static void dw8250_set_termios(struct ua
long rate;
int ret;

- if (IS_ERR(d->clk) || !old)
+ if (IS_ERR(d->clk))
goto out;

clk_disable_unprepare(d->clk);