[PATCH 1/8] regulator: bd71837: Disable voltage monitoring for LDO3/4

From: Matti Vaittinen
Date: Wed Aug 29 2018 - 08:36:29 EST


There is a HW quirk in BD71837. The shutdown sequence timings for
bucks/LDOs which are enabled via register interface are changed.
At PMIC poweroff the voltage for BUCK6/7 is cut immediately at the
beginning of shut-down sequence. This causes LDO5/6 voltage
monitoring to detect under voltage and force PMIC to emergency
state instead of poweroff. Disable voltage monitoring for LDO5 and
LDO6 at probe to avoid this.

Signed-off-by: Matti Vaittinen <matti.vaittinen@xxxxxxxxxxxxxxxxx>
---
drivers/regulator/bd71837-regulator.c | 19 +++++++++++++++++++
include/linux/mfd/rohm-bd718x7.h | 33 ++++++++++++++++++++++++++++++---
2 files changed, 49 insertions(+), 3 deletions(-)

diff --git a/drivers/regulator/bd71837-regulator.c b/drivers/regulator/bd71837-regulator.c
index 0f8ac8dec3e1..a1bd8aaf4d98 100644
--- a/drivers/regulator/bd71837-regulator.c
+++ b/drivers/regulator/bd71837-regulator.c
@@ -569,6 +569,25 @@ static int bd71837_probe(struct platform_device *pdev)
BD71837_REG_REGLOCK);
}

+ /*
+ * There is a HW quirk in BD71837. The shutdown sequence timings for
+ * bucks/LDOs which are controlled via register interface are changed.
+ * At PMIC poweroff the voltage for BUCK6/7 is cut immediately at the
+ * beginning of shut-down sequence. As bucks 6 and 7 are parent
+ * supplies for LDO5 and LDO6 - this causes LDO5/6 voltage
+ * monitoring to errorneously detect under voltage and force PMIC to
+ * emergency state instead of poweroff. In order to avoid this we
+ * disable voltage monitoring for LDO5 and LDO6
+ */
+ err = regmap_update_bits(pmic->mfd->regmap, BD718XX_REG_MVRFLTMASK2,
+ BD718XX_LDO5_VRMON80 | BD718XX_LDO6_VRMON80,
+ BD718XX_LDO5_VRMON80 | BD718XX_LDO6_VRMON80);
+ if (err) {
+ dev_err(&pmic->pdev->dev,
+ "Failed to disable voltage monitoring\n");
+ goto err;
+ }
+
for (i = 0; i < ARRAY_SIZE(pmic_regulator_inits); i++) {

struct regulator_desc *desc;
diff --git a/include/linux/mfd/rohm-bd718x7.h b/include/linux/mfd/rohm-bd718x7.h
index a528747f8aed..e8338e5dc10b 100644
--- a/include/linux/mfd/rohm-bd718x7.h
+++ b/include/linux/mfd/rohm-bd718x7.h
@@ -78,9 +78,9 @@ enum {
BD71837_REG_TRANS_COND0 = 0x1F,
BD71837_REG_TRANS_COND1 = 0x20,
BD71837_REG_VRFAULTEN = 0x21,
- BD71837_REG_MVRFLTMASK0 = 0x22,
- BD71837_REG_MVRFLTMASK1 = 0x23,
- BD71837_REG_MVRFLTMASK2 = 0x24,
+ BD718XX_REG_MVRFLTMASK0 = 0x22,
+ BD718XX_REG_MVRFLTMASK1 = 0x23,
+ BD718XX_REG_MVRFLTMASK2 = 0x24,
BD71837_REG_RCVCFG = 0x25,
BD71837_REG_RCVNUM = 0x26,
BD71837_REG_PWRONCONFIG0 = 0x27,
@@ -159,6 +159,33 @@ enum {
#define BUCK8_MASK 0x3F
#define BUCK8_DEFAULT 0x1E

+/* BD718XX Voltage monitoring masks */
+#define BD718XX_BUCK1_VRMON80 0x1
+#define BD718XX_BUCK1_VRMON130 0x2
+#define BD718XX_BUCK2_VRMON80 0x4
+#define BD718XX_BUCK2_VRMON130 0x8
+#define BD718XX_1ST_NODVS_BUCK_VRMON80 0x1
+#define BD718XX_1ST_NODVS_BUCK_VRMON130 0x2
+#define BD718XX_2ND_NODVS_BUCK_VRMON80 0x4
+#define BD718XX_2ND_NODVS_BUCK_VRMON130 0x8
+#define BD718XX_3RD_NODVS_BUCK_VRMON80 0x10
+#define BD718XX_3RD_NODVS_BUCK_VRMON130 0x20
+#define BD718XX_4TH_NODVS_BUCK_VRMON80 0x40
+#define BD718XX_4TH_NODVS_BUCK_VRMON130 0x80
+#define BD718XX_LDO1_VRMON80 0x1
+#define BD718XX_LDO2_VRMON80 0x2
+#define BD718XX_LDO3_VRMON80 0x4
+#define BD718XX_LDO4_VRMON80 0x8
+#define BD718XX_LDO5_VRMON80 0x10
+#define BD718XX_LDO6_VRMON80 0x20
+
+/* BD71837 specific voltage monitoring masks */
+#define BD71837_BUCK3_VRMON80 0x10
+#define BD71837_BUCK3_VRMON130 0x20
+#define BD71837_BUCK4_VRMON80 0x40
+#define BD71837_BUCK4_VRMON130 0x80
+#define BD71837_LDO7_VRMON80 0x40
+
/* BD71837_REG_IRQ bits */
#define IRQ_SWRST 0x40
#define IRQ_PWRON_S 0x20
--
2.14.3