[PATCH 3/8] regulator: dt bindings: add BD71847 device-tree binding documentation
From: Matti Vaittinen
Date: Wed Aug 29 2018 - 08:37:43 EST
Add ROHM BD71847 Power Management IC regulator binding information to
device-tree binding documents.
Signed-off-by: Matti Vaittinen <matti.vaittinen@xxxxxxxxxxxxxxxxx>
---
.../devicetree/bindings/regulator/rohm,bd71837-regulator.txt | 12 +++++++++---
1 file changed, 9 insertions(+), 3 deletions(-)
diff --git a/Documentation/devicetree/bindings/regulator/rohm,bd71837-regulator.txt b/Documentation/devicetree/bindings/regulator/rohm,bd71837-regulator.txt
index 76ead07072b1..4b98ca26e61a 100644
--- a/Documentation/devicetree/bindings/regulator/rohm,bd71837-regulator.txt
+++ b/Documentation/devicetree/bindings/regulator/rohm,bd71837-regulator.txt
@@ -1,7 +1,9 @@
-ROHM BD71837 Power Management Integrated Circuit (PMIC) regulator bindings
+ROHM BD71837 and BD71847 Power Management Integrated Circuit regulator bindings
Required properties:
- - regulator-name: should be "buck1", ..., "buck8" and "ldo1", ..., "ldo7"
+ - regulator-name: should be "buck1", ..., "buck8" and "ldo1", ..., "ldo7" for
+ BD71837. For BD71847 names should be "buck1", ..., "buck6"
+ and "ldo1", ..., "ldo6"
List of regulators provided by this controller. BD71837 regulators node
should be sub node of the BD71837 MFD node. See BD71837 MFD bindings at
@@ -16,10 +18,14 @@ disabled by driver at startup. LDO5 and LDO6 are supplied by those and
if they are disabled at startup the voltage monitoring for LDO5/LDO6 will
cause PMIC to reset.
-The valid names for regulator nodes are:
+The valid names for BD71837 regulator nodes are:
BUCK1, BUCK2, BUCK3, BUCK4, BUCK5, BUCK6, BUCK7, BUCK8
LDO1, LDO2, LDO3, LDO4, LDO5, LDO6, LDO7
+The valid names for BD71847 regulator nodes are:
+BUCK1, BUCK2, BUCK3, BUCK4, BUCK5, BUCK6
+LDO1, LDO2, LDO3, LDO4, LDO5, LDO6
+
Optional properties:
- Any optional property defined in bindings/regulator/regulator.txt
--
2.14.3