Re: [PATCH] ASoC: tlv320aic31xx: Remove regulator notification handling

From: Mark Brown
Date: Mon Sep 03 2018 - 07:30:45 EST


On Fri, Aug 31, 2018 at 01:17:37PM -0500, Andrew F. Davis wrote:
> The notification handler sets the reset line but never re-enables it
> as no one is listening for an enable event, this is certainly broken
> and was most likely just copied from other CODECs, remove this code.

Why not fix it? The usual pattern would be to take the CODEC out of
reset when bringing the bias back to standby.

Attachment: signature.asc