Re: [PATCH 1/5] dt-bindings: sun4i-drm: drop second PLL from A64 HDMI PHY binding
From: Maxime Ripard
Date: Mon Sep 10 2018 - 10:23:04 EST
On Fri, Sep 07, 2018 at 03:22:30PM +0800, Icenowy Zheng wrote:
> By experiments it seems that the A64 HDMI PHY is not able to use the
> second video PLL as the clock parent.
>
> Drop pll-1 from the device tree binding of A64 HDMI PHY.
>
> Signed-off-by: Icenowy Zheng <icenowy@xxxxxxx>
> ---
> Documentation/devicetree/bindings/display/sunxi/sun4i-drm.txt | 1 -
> 1 file changed, 1 deletion(-)
>
> diff --git a/Documentation/devicetree/bindings/display/sunxi/sun4i-drm.txt b/Documentation/devicetree/bindings/display/sunxi/sun4i-drm.txt
> index f8773ecb7525..62034039cee1 100644
> --- a/Documentation/devicetree/bindings/display/sunxi/sun4i-drm.txt
> +++ b/Documentation/devicetree/bindings/display/sunxi/sun4i-drm.txt
> @@ -114,7 +114,6 @@ Required properties:
>
> H3 and A64 HDMI PHY require additional clocks:
> - pll-0: parent of phy clock
> - - pll-1: second possible phy clock parent (A64 only)
You shouldn't need to do this. The DT is about the hardware. The fact
that we haven't figured out how to use it is quite irrelevant, and can
change in the future, unlike this binding.
Maxime
--
Maxime Ripard, Bootlin
Embedded Linux and Kernel engineering
https://bootlin.com
Attachment:
signature.asc