On Tue, Sep 25, 2018 at 06:46:51AM -0400, Brian Masney wrote:
> The following commits used IRQ_TYPE_NONE since that matched what was
> already in the file and I do not have access to the datasheets for
> these devices. After these patches were submitted, commit dcf145011400
> ("ARM: dts: qcom-msm8974: change invalid flag IRQ NONE to valid value")
> changed all of these values to IRQ_TYPE_LEVEL_HIGH. This patch corrects
> the IRQ type for these two commits:
>
> commit bd9392507588 ("ARM: dts: qcom: msm8974-hammerhead: add device
> tree bindings for ALS / proximity")
>
> commit fe8d81fe7d9a ("ARM: dts: qcom: msm8974-hammerhead: add device
> tree bindings for mpu6515")
>
> Prior to these patches, I was having issues with the bmp280 sensor
> returning temperature / pressure skipped errors, however these errors
> have gone away with these patches.
>
> Patches were tested on a LG Nexus 5 (hammerhead) phone.
>
> Signed-off-by: Brian Masney <masneyb@xxxxxxxxxxxxx>
> ---

Thanks for submitting this fix. I added it and it will be part of the pull
request.

Thanks,

Andy